Hazard Index: 0
The formula
Hazard Index = GenX/10 + PFBS/2000 + PFNA/10 + PFHxS/10, with each result in ppt. Each divisor is EPA's health-based water concentration for that PFAS. The limit is 1, and it applies to mixtures of two or more of these four PFAS.
Compliance uses the running annual average of quarterly Hazard Index results, rounded to one significant digit. EPA counted a UCMR 5 average as above the limit at 1.5 or more.
Worked example from EPA
Quarter 1: GenX 5, PFBS 5, PFNA not detected, PFHxS 3 ppt. 5/10 + 5/2000 + 0 + 3/10 = 0.8025.
Note: on May 18, 2026 EPA proposed rescinding the Hazard Index limit. The proposal is not final.
Source: EPA Hazard Index fact sheet (April 2024).
Information only, not medical advice. Health disclaimer.